Cla-Val Headquarters
Cla-Val Headquarters
  • Видео 79
  • Просмотров 1 136 462
The most effective way to stop cavitation in Automatic Control Valves
Bobby, the Valve Guy, is back! This time he is talking about cavitation and the applications where it is most likely to occur. Watch this quick video to learn how to effectively stop cavitation from destroying your valves.
Просмотров: 2 283

Видео

Cla-Val Bobby Explains Pump Control
Просмотров 5 тыс.3 года назад
Bobby the Valve Guy is back. This time he’s talking about the importance of pump control valves in piping systems and the best way to prevent water hammer.
Cla-Val Field Service Team
Просмотров 1,2 тыс.3 года назад
Cla-Val’s Western Region Field Service Team goes above and beyond when it comes to keeping your automatic control valves in tip-top shape. Watch this video for an overview of their capabilities.
Bobby The Valve Guy L2V Service
Просмотров 2013 года назад
Bobby, the Valve Guy, and his sidekick Kenny, the Service Tech, explain how to get the most out of a service call by using Cla-Val’s free app Link2Valves. Let the efficiency begin! @Clavalusa
Cla Val 60 11 Booster Pump Control Valve
Просмотров 5 тыс.3 года назад
Cla-Val Booster Pump Control Valves provide exceptional protection against pipeline surges caused by the starting and stopping of Booster Pumps. This animation gives a realistic view of how they operate.
Bobby Explains the Difference Between Pressure Relief Valves and Surge Valves - CVAP
Просмотров 3,9 тыс.3 года назад
This animation explains when to use a pressure relief valve and when a surge valve might be a better choice.
CLAVAL Deep Well Pump Control Valves
Просмотров 2,4 тыс.3 года назад
Get an insider’s view of how Cla-Val 61-02 Deep Well Pump Control Valves operate.
How PRVs Really Work
Просмотров 52 тыс.3 года назад
Automatic Control Valve Aficionado, Bobby explains how Cla-Val Pressure Reducing Valves work in a water distribution system.
Válvula de registro WEB Link2Valves
Просмотров 1313 года назад
Válvula de registro WEB Link2Valves
Registro principal de registro de la aplicación Link2Valves
Просмотров 823 года назад
Registro principal de registro de la aplicación Link2Valves
Descripción general de la aplicación Link2Valves
Просмотров 933 года назад
Descripción general de la aplicación Link2Valves
Válvula de registro de la aplicación Link2Valves
Просмотров 1393 года назад
Válvula de registro de la aplicación Link2Valves
Sitio de registro de la aplicación Link2Valves
Просмотров 873 года назад
Sitio de registro de la aplicación Link2Valves
Navegación básica de Link2Valves WEB
Просмотров 1043 года назад
Navegación básica de Link2Valves WEB
Sitio de Internet - Documentando un Sitio WEB Link2Valves
Просмотров 783 года назад
Sitio de Internet - Documentando un Sitio WEB Link2Valves
Administrador WEB de Link2Valves
Просмотров 773 года назад
Administrador WEB de Link2Valves
Geolocalización WEB de Link2Valves
Просмотров 1013 года назад
Geolocalización WEB de Link2Valves
Válvula de registro WEB Link2Valves
Просмотров 373 года назад
Válvula de registro WEB Link2Valves
Registros de mantenimiento de registro WEB de Link2Valves
Просмотров 2723 года назад
Registros de mantenimiento de registro WEB de Link2Valves
Cla Val 90 21 Fire Protection PRV IOM
Просмотров 33 тыс.3 года назад
Cla Val 90 21 Fire Protection PRV IOM
Cla Val 50B 4KG1 Fire Protection Pressure Relief Valve IOM
Просмотров 18 тыс.3 года назад
Cla Val 50B 4KG1 Fire Protection Pressure Relief Valve IOM
Cla-Val 100-01 Hytrol Main Valve Rebuild
Просмотров 18 тыс.3 года назад
Cla-Val 100-01 Hytrol Main Valve Rebuild
Cla Val CRL & 55L Pressure Relief Pilot Rebuild
Просмотров 2,4 тыс.3 года назад
Cla Val CRL & 55L Pressure Relief Pilot Rebuild
Cla-Val Asia Pacific Waterworks Product Overview
Просмотров 9453 года назад
Cla-Val Asia Pacific Waterworks Product Overview
Cla Val CRL 60 Pressure Relief Pilot Rebuild
Просмотров 7 тыс.3 года назад
Cla Val CRL 60 Pressure Relief Pilot Rebuild
Cla Val 90 01 PRV Troubleshooting
Просмотров 17 тыс.3 года назад
Cla Val 90 01 PRV Troubleshooting
Cla Val 90 01 PRV Start Up
Просмотров 10 тыс.3 года назад
Cla Val 90 01 PRV Start Up
Cla Val 90 01 PRV Live Demo of Operation
Просмотров 40 тыс.3 года назад
Cla Val 90 01 PRV Live Demo of Operation
Cla Val 55L 60 Fire Pump Casing Pressure Relief Valve Rebuild
Просмотров 6 тыс.3 года назад
Cla Val 55L 60 Fire Pump Casing Pressure Relief Valve Rebuild
Servicing Cla-Val control valves in Waterworks piping systems
Просмотров 2593 года назад
Servicing Cla-Val control valves in Waterworks piping systems

Комментарии

  • @vedangapte1258
    @vedangapte1258 20 дней назад

    Can you explain the operation of pressure reducing valve in detail?

  • @UnfoldU
    @UnfoldU Месяц назад

    Can the crd be shut when it leaks

  • @maxtaxplusdotnet
    @maxtaxplusdotnet Месяц назад

    🙌

  • @ugow850
    @ugow850 2 месяца назад

    Hi. Is it better to place PRV before or after a solenoid valve?

  • @Randallsixx13
    @Randallsixx13 2 месяца назад

    Very informative. Thank you.

  • @SuperLusername
    @SuperLusername 2 месяца назад

    How does discharge pressure remain 50psi if you change the flow? Doesnt opening the valve more, reduce the resistance pressure on the inflow? And thus the discharge pressure should be higher?

  • @canlam5697
    @canlam5697 2 месяца назад

    Question: if your setting is 50 psi on the discharge side when you close it from flowing, Does the pressure on the discharge side increase or remain at 50 psi.

  • @user-jx2lu8ru2v
    @user-jx2lu8ru2v 3 месяца назад

    Can i throttle relief valve flow rate ?

  • @piping2024
    @piping2024 3 месяца назад

    🙏🙏

  • @khaiurddinkhan6064
    @khaiurddinkhan6064 3 месяца назад

    Nice 👍

  • @kalathilasokan752
    @kalathilasokan752 4 месяца назад

    Thank you🎉

  • @Hunting334
    @Hunting334 4 месяца назад

    👍👍👍👍👍👍👍

  • @Hunting334
    @Hunting334 4 месяца назад

    👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍

  • @WhosYerFadder
    @WhosYerFadder 4 месяца назад

    thanks bobby

  • @Hunting334
    @Hunting334 4 месяца назад

    👍👍👍👍👍👍👍

  • @willynillynilky5226
    @willynillynilky5226 5 месяцев назад

    These valves are terrible. Swing checks are more reliable

  • @cashapp_free_money
    @cashapp_free_money 5 месяцев назад

    "The only limit to our realization of tomorrow will be our doubts of today." - Franklin D. Roosevelt

  • @humairasamiya6729
    @humairasamiya6729 5 месяцев назад

    I want know about crd of banglavartion

  • @jefffuchs2667
    @jefffuchs2667 6 месяцев назад

    Some things to keep in mind when installing an inline valve 1) before breaking pipe, run your probe along each side of the pipe into the walls of the trench and ensure you don’t have a coupling close by. 2) throw some jacks under the pipe on each side. This will ensure your pipe doesn’t sag and pull out of the coupling 3) To minimize using short pup pieces of pipe and multiple leak points - Use and FCA on one and and change your valve off that then a longer stick of pipe and 1 coupling for the other side 4) Always, always, always grease and wax tap your valve and couplings - this will preserve the assembly and bolts and make it easy for the next guy who has to dig it up and repair it in 30-40 years

  • @sulemanabdullah4009
    @sulemanabdullah4009 7 месяцев назад

    lovely thank u so much.

  • @a.m347
    @a.m347 7 месяцев назад

    6:24 is wrong Because when the valve open it will not allow the flow from downstream to the main valve It is one direction flow from the main valve to downstream so the correct it will allow the flow in the top chamber to be evacuated through the pilot to downstream not vice versa

  • @sangrambarla8587
    @sangrambarla8587 7 месяцев назад

    I'm from Scholar academy 🥳

  • @a.m347
    @a.m347 7 месяцев назад

    No more valuable explanation like that 😍😍❤️🙏

  • @wat3rdog25
    @wat3rdog25 7 месяцев назад

    Current app ask for parent organization. The drop down has no option other than select. Unable to save new site.

  • @jahangirkabir574
    @jahangirkabir574 8 месяцев назад

    Nice presentation

  • @mradulsaraswat08
    @mradulsaraswat08 9 месяцев назад

    Good day Claval team We are having a very rough experience in getting quotation from your UAE representatives. From past 14 days we are chasing them and till today the quote has not been provided. And that being the case after we gave them the model number and specifications. If they had to choose it, I wonder how long it would have been delayed. No doubts, your valves might be good but the supporting staff is not that great to be honest.

  • @a.m347
    @a.m347 10 месяцев назад

    The working principle for this station is the same for the fire protection jokey and Electric pumps which are connected in parallel if there's small pressure drop in the system due to leakage the pressure will be drop until it reaches the setting point of jokey pump so it will comes to service If the pressure dropped more due to sprinklers operation or hose cabinet the pressure will be reduced more until reaching the setting point of the electric pump it will come also to service to fulfill the demand of higher flow and so on. So by this configuration we keeping the larger PRV from continuous operation to protect it from cavitation for long life operation. Also this station may be working alternatively during maintenance works in one side branch keeping the other working delivering water to the system.

  • @coreysullivan7401
    @coreysullivan7401 Год назад

    What does CLR STAND FOR?

  • @paulgibson2591
    @paulgibson2591 Год назад

    Magic

  • @msalazar89
    @msalazar89 Год назад

    Make a video for the cds 7 with the delay feature please

  • @ttt8878
    @ttt8878 Год назад

    Thanks 👍🏿

  • @nourel-moubarekel-tayeb8215
    @nourel-moubarekel-tayeb8215 Год назад

    Hi is a pressure relief valve considerate as a CRL ?

  • @jmoe724
    @jmoe724 Год назад

    Do you have a video that explain the smaller tubes that tie into the pilot assembly .

  • @kremesti
    @kremesti Год назад

    fantastic video thank u

  • @kremesti
    @kremesti Год назад

    This is amazing

  • @kremesti
    @kremesti Год назад

    what is CRL????

  • @yanarifin9343
    @yanarifin9343 Год назад

    Support membran sir?

  • @mdarifwaquar3270
    @mdarifwaquar3270 Год назад

    Very nice 👍🏻 sir

  • @ranger7915
    @ranger7915 Год назад

    Please make video on this float level control and maintenance

  • @ranger7915
    @ranger7915 Год назад

    Ur service available at united Arab Emirates?

  • @c.nobody3378
    @c.nobody3378 Год назад

    Big foot print on the system.. also looks annoying to work on in the field.

    • @hanruobing6924
      @hanruobing6924 Год назад

      We are manufacturer specialized in auto and marine diesel engine parts since 1952. Our main parts are EURO II system: plunger, nozzle , delivery valves, head rotors, repair kits, etc. Common rail system: Injector complete and injector spare parts for CATERPILLAR, DENSO, DELPHI , BOSCH, SIMENS, CUMMINS, etc. If you have any inquiries, pls do not hesitate to contact me

    • @atulsharma2325
      @atulsharma2325 6 дней назад

      ​@@hanruobing6924where to contact u

  • @malikosmanahmed110
    @malikosmanahmed110 Год назад

    Please I need to know how to adjust Deluge valve CLA-VAL 134E-O5

  • @samirsebai8463
    @samirsebai8463 Год назад

    Thanks for your video

  • @maiconmartins1910
    @maiconmartins1910 Год назад

    Tem em português

  • @hectorpadrongarcia8608
    @hectorpadrongarcia8608 Год назад

    Sería genial oírlo en español, saludos!

  • @hectorpadrongarcia8608
    @hectorpadrongarcia8608 Год назад

    Seria genial oírlo en español, saludos!

  • @simplevideos9965
    @simplevideos9965 Год назад

    Good 👍😊

  • @mustafaemirhankuru8422
    @mustafaemirhankuru8422 Год назад

    That was a good tutorial thank you

  • @eesquib3
    @eesquib3 Год назад

    How does this work if system also has a float to call for pump run

  • @junolajato6556
    @junolajato6556 Год назад

    Hi George we are using your product in our company and some other brand. I just have noticed the design of the valve body is much larger compare to other brand (size 300mm). What is the advantage of that having a larger body?